TitleProduct

Oxygen Probe

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2018-10-10 03:36

  • Browse the number:

    158

Send an inquiries

Company Profile

Yueqing ChangFeng Temperature Measuring Devices Co.,Ltd

By certification [File Integrity]

Contact:changfen(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website:http://www.cfsampler.com/ http://www.sin-ko.com/com/changfen/

PRODUCT DETAILS

1. Outline

Oxygen, which exists in molten steel, plays a decisive role in the quality of molten steel, yield and consumption of ferroalloys. With the continuous expansion of the production of boiling, semi-killed and aluminium deoxidized continuous casting steels and the wide application of molten steel refining technology, it is urgent to know the oxygen content in molten steel quickly, accurately and directly in order to control steelmaking operation, improve quality and reduce consumption. Solid electrolyte concentration difference oxygen determination technology is developed to meet these requirements.


2. Principle

Solid electrolyte oxygen concentration determination consists of two half cells, one is a reference cell with known oxygen partial pressure, and the other is molten steel with oxygen content to be measured. Two half-batteries are connected with oxygen ion solid electrolyte to form an oxygen concentration cell. The oxygen content can be determined by measuring the oxygen potential and temperature.

 

3. Main technical parameters

Measurement   site

Reference    material

 Measurement range

Measurement    accuracy

 Yield

 Response time

 In furnace

 Mo/MoO2

Cr/Cr2O3

50~1200PPm

10%

Oxygen≥90%

temperature≥98%

≤8s

In bag

Cr/Cr2O3

1~100PPm

When≥10PPm    Error 10%

when≤10PPm    Error 1PPm


4. Usage

A. Strictly check the probe, test the grab and instrumentation system to ensure integrity.

B. The oxygen probe is mounted on the test gun. The instrument pointer (digital display) returns to zero to indicate good conduction and direction measurement.

C. When measuring, the probe should not stay in molten steel for more than 10 seconds, otherwise it is easy to burn the test gun.


5. Type Specification of Oxygen Detector

Product Name: Oxygen Probe

Product Model: ZCDY - (S B R) Specification: 1X38X1200

according to ICE584/IPTS68 standard
Type S(Pt-10%Rh / Pt): 400~1760℃
Type R(Pt-13%Rh /Pt): 400~1760℃
Type B(Pt-30%Rh /Pt-6%Rh): 600~1800℃

Linear measurement range

Oxygen potential: -    300 ~+300 mV

Oxygen potential: -    300 ~+300 mV
Allowance: <10 ppm,    +1 ppm
When the value is over    10 ppm, it is (+5%) of the measured value.

Measuring range

Output Oxygen EMF Consistency: Not More than 2mV

Requirements: conduction, no reverse pole

The measuring range of aluminium content is 0.01%~0.10%.

Oxygen Battery   3-6s
Thermocouple    2-5s
Whole process    3-8 s

Response time

Thermocouple Accuracy:    1200-1760 C Allowance: +3 C

The length of paper    tube is 1.2m, which can be customized by users.

Rate of success: >    98%

Reference material:    Mo/Cr+Cr203//Zr02.MgO//(O)Fe/Fe

Applicable to LF, RH,    DH, tundish, etc.

Interface: Universal

Packaging: carton 1X25PCS


6. Basic Composition of Oxygen Probe

 


7. oxygen probe accessories

8.Friendship

We always take honesty and trustworthiness as the company's criterion. Customers first is what we have been advocating and pursuing. Friendship and friendly cooperation make us have sincere friendship.

http://www.cfsampler.com/